Skip to main content

Table 3 Pre- and intraoperative mean dose rates during SLN procedure (2-day protocol) with a 150 MBq Tc-99 m nanocolloid at various distances to the radiation source/patient

From: 10-Year experience regarding the reliability and morbidity of radio guided lymph node biopsy in penile cancer patients and the associated radiation exposure of medical staff in this procedure

Distance

Mean dose rate (μSv/h)

Preoperatively

 

 Directly on the injection needle (0 cm)

200

 Hands of nuclear medicine physician (10 cm)

100

 Position of nuclear medicine physician (30 cm)

10

 Position assisting staff (50 cm)

2

Intraoperatively (prior to resection of the tumour)

 

 Hands of surgeon (10 cm)

20

 Surgeon (30 cm)

2.2

 Surgical staff/physician (50 cm)

0.5

 Anesthetist (200 cm)

0.13

Intraoperatively (after resection of the tumour)

 

 Directly on the sample (0 cm)

15

 Hands of surgeon (10 cm)

1.5

 Surgeon (30 cm)

1.1

 Surgical staff/physician (50 cm)

0.3