Skip to main content

Table 4 Pre- and intraoperative mean radiation exposure of the clinical staff by SLNB in different tumour entities

From: 10-Year experience regarding the reliability and morbidity of radio guided lymph node biopsy in penile cancer patients and the associated radiation exposure of medical staff in this procedure

 

Tumour entity

 

Penile carcinoma

Malignant melanoma

Breast cancer

applied activity [MBq]

Tc-99 m-labelled nanocolloid

150

2-day protocol

45

1-day protocol

150

2-day protocol

 

mean

Effective Dose E [μSv]

mean

Organ-dose of the hands Hhands [μSv]

mean

Effective Dose E [μSv]

mean

Organ-dose of the hands Hhands [μSv]

mean

Effective Dose E [μSv]

mean

Organ-dose of the hands Hhands [μSv]

clinical staff

      

nuclear medicine physician

105

20

2

10

0.6

10

nuclear medicine technologist

0.5

10

0.5

10

0.2

10

surgeon

4.0

100

0.5

7

0.6

5

anesthetist

1.0

-

0.7

-

0.4

-

surgical staff

1.0

-

0.5

-

0.4

-