Skip to main content

Table 2 Analysis of GEE parameter estimates to identify the factors affecting the technical success of fluoroscopy-guided trans-urethral exchange of double-J ureteral stents

From: Fluoroscopy-guided trans-urethral exchange of double-J ureteral stents

Parameters

 

Estimate

Standard error

95% confidence limits

Z

Pr >|Z|

95% confidence limits

OR

LL

UL

Intercept

 

 − 0.6838

0.8586

 − 2.3667

0.999

 − 0.8

0.4258

0.505

0.094

2.716

Sex

Female

3.4145

1.1109

1.2371

5.5919

3.07

0.0021

30.402

3.446

268.235

Sex

Male

0

0

0

0

     

Change

 

0.8713

0.4174

0.0532

1.6894

2.09

0.0369

2.390

1.055

5.416

Obstruction level

Abdominal, intravesical

2.2188

0.8308

0.5904

3.8471

2.67

0.0076

9.196

1.805

46.860

Obstruction level

Pelvic

0

0

0

0