Skip to main content

Table 4 Comparison of the urethra parameters by Perineal ultrasonography between SUI and NSUI groups

From: Perineal ultrasound to assess the urethral spatial movement in stress urinary incontinence in women

Group

AMVD

BMVD

CMVD

DMVD

SUI

14.6 ± 7.0 mm

11.9 ± 5.6 mm

8.5 ± 4.9 mm

6.8 ± 3.7 mm

NSUI

10.0 ± 4.1 mm

8.2 ± 3.4 mm

7.1 ± 2.7 mm

6.1 ± 3.5 mm

P

 < 0.05

 < 0.05

 < 0.05

 > 0.05

  1. AMVD, BMVD, CMVD, DMVD are described as the difference in the distance at urethral coordinates (x coordinates, y coordinates) form the rest to Valsalva