Skip to main content

Two-year outcomes of surgeon-tailored trans obturator tape for female stress urinary incontinence: a randomized, comparative, trial with traditional trans obturator tape

Abstract

Background

Previously, we presented the short-term outcomes of surgeon-tailored mesh in patients with SUI undergoing TOT. In this report, we aim to highlight the two-year outcomes of surgeon tailored mesh in terms of subjective and objective cure rates, as well as late complications.

Methods

We performed a randomized, open-label comparative trial that recruited women with SUI who were scheduled to undergo TOT. Eligible patients were randomly allocated in a 1:1 ratio to receive traditional TOT mesh or surgeon-tailored polyethylene mesh. All patients were followed up for two years.

Results

At the end of the follow-up, there were 13 women in the traditional TOT mesh group and 14 patients in the surgeon-tailored polyethylene mesh group. Concerning the primary outcome of the present study, the cure rate was 100% in the surgeon-tailored polyethylene mesh (n = 14) and 92.9% in the traditional TOT mesh group (p = 0.39). One woman reported improved symptoms in the traditional TOT mesh group. There were no reported failures in both groups. Concerning safety, the incidence of de novo urgency was 0% in the surgeon-tailored polyethylene mesh group, compared to 7.1% in the traditional TOT mesh group (p = 0.34). None of the women in both groups reported mesh erosions, dyspareunia, or need for reoperation.

Conclusion

Surgeon-tailored mesh for patients undergoing TOT is a cost-effective technique, which has comparable long-term outcomes, in terms of cure rate and complications, to the traditional costly meshes. Larger multicentre studies should confirm our results.

Peer Review reports

Background

Stress urinary incontinence (SUI) is a prevalent disorder that is characterized by leakage of urine after physical stress [1]. Surgical procedures are widely performed for women with failed conservative management or women seeking definitive treatment [2]. Mid-urethral sling (MUS) is a highly effective, minimally-invasive, surgical approach for SUI that is based on the passing of a small band of a synthetic mesh into either the retropubic space (known as tension-free vaginal tape, TVT) or through the obturator foramen (known as trans-obturator tape, TOT or TVT-O, through the inside-out route) [3]. Previous reports showed that MUS achieves a cure rate of up to 94% [4], with a low risk of postoperative complications, such as visceral injuries and retention [5]. The current body of evidence demonstrated a well-established short- and long-term efficacy profile of MUS [6,7,8].

Nonetheless, TOT is a costly procedure, especially in developing countries, due to the need for prefabricated slings and specific needles or passers to reduce the risk of injuries to surrounding structures [9]. Thus, a number of surgeon-tailored meshes were proposed to reduce the cost of the procedure, with maintaining the postoperative and long-term outcomes [10]. Previously, we presented the short-term outcomes of surgeon-tailored mesh in patients with SUI undergoing TOT [11]. In this report, we aim to highlight the two-year outcomes of surgeon-tailored mesh in terms of subjective and objective cure rates, as well as late complications.

Materials and methods

The protocol of the current trial was approved by the local ethics committee of the Faculty of Medicine for Girls Al-Azhar University, Cairo, Egypt. All procedures run in compliance with the standards of the Declaration of Helsinki [12]. We prepared the following manuscript in concordance with CONSORT guidelines [13].

Study design and patients

We performed a randomized, open-label comparative trial that recruited women with SUI who were scheduled to undergo TOT at Al Zahraa University Hospital through the period from the end of December 2016 to the end of April 2021. Women were considered eligible if they fulfilled the following criteria: female patients aged more than 18 years old, patients with an established diagnosis of genuine SUI, and patients who did not exhibit a significant response to conservative management. We included women regardless of their parity status. On the other hand, we excluded patients with mixed incontinence, urge incontinence, acute infection, malignancies, overactive bladder, bleeding disorders, internal sphincteric deficiency, concomitant prolapse, post-void residual urine more than 150 cc, and/or bladder capacity less than 250 cc. Pregnant and lactating women were excluded as well.

Eligible patients were randomly allocated in a 1:1 ratio to receive traditional TOT mesh or surgeon-tailored polyethylene mesh by a computer software program (www.Randmizer.org), and allocation sequences were done by opaque closed envelopes.

Study’s procedures and follow-up

All eligible women were subjected to standardized preoperative history taking and local gynecological examination. Patients underwent routine abdominopelvic ultrasonography (US) and cystometry by Andromeda Urodynamic apparatus.

The full surgical procedure was described previously [11]. After placing the patients in the lithotomy position, the surgeon introduced a 16 French catheter into the bladder and inflated the balloon. Then, the vaginal wall was incised in the midline for a one-cm distance, approximately one cm from the urethral meatus. This was followed by the incision of mucosa and submucosa, and dissection of periurethral fascia bilaterally towards the inferior pubic ramus. A skin incision was then performed medial to the genito-femoral fold at the base of the adductor longus tendon, approximately at the level of the clitoris. A needle with fixed tape was introduced from the obturator to the vaginal incisions. Patients in the surgeon-tailored polyethylene mesh group received 30 × 1 cm polypropylene strips, which were prepared by splitting the 30 × 30 prolene mesh and re-sterilized by plasma machine. All patients were asked to cough to assess continence after the bladder was filled with 250 ml saline. The skin and vaginal incisions were closed by 3-0 vicryl in sub-cuticular and interrupted fashions, respectively. All patients were followed up for two years.

Study's outcomes

The primary outcome of the present study was the two-year objective success rate. The objective success year was categorized into the following three categories: cure, which donates that the women have no stress-induced urine leak on cough test and that the women exhibited satisfactory control of their urine; improved, which donates that the women had urine leak on severe exertion only and they express subjective improvement in their symptoms; and failure, which donates that the women still exhibit the same level of preoperative urine leak on cough test and they are not satisfied with their condition. The secondary outcomes of this study included the incidence of late postoperative complications, such as reoperation, mesh erosion, de novo urgency, and dyspareunia.

Statistical analysis

Retrieved data were summarized and processed with IBM SPSS statistical software (version 25). Frequencies were used to describe gynecological history, Ultrasound findings, postoperative complications, and success rates. On the other hand, age, ALPP, duration surgery, and hospital stay were summarized, according to normality, into mean (± standard deviation [SD]) or median (range). The hypothesize of significant differences between the type of mesh and primary or secondary outcomes was challenged using the independent t-test or Chi-square test for continuous and categorical data, respectively. P value < 0.05 was regarded as statistically significant.

Results

Initially a total of 63 women were screened for eligibility; of them, 35 women were deemed eligible and 30 of them agreed to sign the informed consent. The 30 women were randomly allocated to the traditional TOT mesh (n = 15 women) or surgeon-tailored polyethylene mesh (n = 15 women). At the end of follow-up, there were 13 women in the traditional TOT mesh group and 14 patients in the surgeon-tailored polyethylene mesh group (Fig. 1).

Fig. 1
figure 1

Checklist of the study

The mean age between the traditional TOT mesh and the surgeon-tailored polyethylene mesh groups was comparable (46.79 ± 7.567 vs. 40.67 ± 7.93 years old; p = 0.85). There were no significant differences between both groups in terms of parity (p = 0.36), number of previous vaginal deliveries (p = 0.13), number of previous Cesarean section (p = 0.18), use of pad (p = 0.63), and residual urine by US (p = 0.39). The mean operative time was slightly lower in the surgeon-tailored mesh group (15.67 ± 2.06 vs. 20.86 ± 3.35 min in the traditional TOT mesh group), without statistically significant difference (p = 0.075). Likewise, the mean ALPP was comparable between both groups (25.72 ± 6.87 vs. 33.72 ± 9.73, respectively; p = 0.51). The incidence of intraoperative vaginal wall injury was 0% in the surgeon-tailored polyethylene mesh group, compared to 7.7% in the traditional TOT mesh group (p = 0.34). The incidence of UTI or vaginal infection (23.1% versus 0% in the traditional TOT mesh and the surgeon-tailored polyethylene mesh groups, respectively), with p = 0.088 (Table 1).

Table 1 Perioperative Characteristics of the Follow-up Cohort (n = 27)

Concerning the primary outcome of the present study, the cure rate was 100% in the surgeon-tailored polyethylene mesh (n = 14) and 92.3% in the traditional TOT mesh group (p = 0.39). One woman reported improved symptoms in the traditional TOT mesh group. There were no reported failures in both groups (Fig. 2). With regard to safety, the incidence of de novo urgency was 0% in the surgeon-tailored polyethylene mesh group, compared to 7.7% in the traditional TOT mesh group (p = 0.34). None of the women in both groups reported mesh erosions, dyspareunia, or need for reoperation (Table 2).

Fig. 2
figure 2

Outcome of the procedure

Table 2 Safety outcomes of the follow-up cohort (n = 27)

Discussion

Although there is a plethora of evidence about the efficacy and safety of surgical modalities for SUI, the published literature still lacks high-quality evidence about the long-term outcomes of new approaches aiming to improve the financial outcomes of these modalities [14, 15]. Thus, we conducted the present trial to highlight the two-year outcomes of surgeon tailored mesh in terms of subjective and objective cure rates and late complications. Our results showed the lack of statistically significant difference between surgeon-tailored mesh and traditional mesh in terms of cure rate (100% vs. 85.7%, respectively). Both techniques had comparable de novo urgency, mesh erosion, and dyspareunia rates at the end of the second year of follow-up.

TOT is a widely utilized, minimally-invasive technique that has proven its usefulness in patients with SUI; the technique is associated with optimal cure rates and diminished risks of major postoperative complications, such as injuries to surrounding structures and retention [3, 5]. Previous reports showed that the TOT exhibited acceptable levels of cure rate and safety profile on long-term follow-up among women with SUI [8, 16]. TOT was proven to be associated with lower direct cost than laparoscopic Burch colposuspension [17]. However, it is well-recognized that the TOT procedure is associated with a considerable financial burden on the patients and healthcare systems due to the high cost of its equipment, including meshes and passengers. Mesh erosion can put a further cost burden on the patients [18]. Thus, the need for alternative, less costly alternatives were deemed critical, particularly in developing countries [19]. Previous reports showed that the use of tailored polypropylene mesh resulted in satisfactory results and a less costly procedure for patients with SUI. Our previous report confirmed such findings showing that the surgeon-tailored mesh was associated with a high cure rate similar to traditional mesh [11]. Nonetheless, the current body of evidence shows scarcity of the long-term outcomes of this modified cheap approach. The present report found that the surgeon-tailored was associated with high cure rates at the end of the second year of follow-up, which donates its satisfactory long-term outcomes. In concordance with our findings, ElSheemy et al. [9], showed that the use of tailored polypropylene mesh in women undergoing TVT was associated with a cure rate of 91%. Another long-term comparative study by the same group showed that the tailored polypropylene mesh was associated with a comparable cure rate to the traditional mesh in women undergoing TVT [10]. In a Chinese report, Chen et al. [18], reported that the tailored polypropylene mesh led to a cure rate of 96% at the end of the first year of follow-up. Our findings are in line with short and medium-term results reported by Imamura et al. [15], in which the TOT achieved higher cure rates than other procedures.

The surgical management of SUI can be associated with a high rate of treatment failure and reoperation. It was previously noted that up to 4% of patients undergoing surgery need reoperation due to recurrent SUI. Nonetheless, the rate of reoperation is not consistent across various surgical approaches for SUI [20]. TOT is thought to increase the risk of reoperation due to synthetic mesh, which may be exposed in the long term and need removal. The synthetic mesh may also lead to chronic pain and voiding dysfunction requiring reoperation [3]. Several risk factors were implicated in the need for reoperation among women undergoing TOT, such as obesity, diabetes, revision surgery, and mixed UI [21]. More recently, Illiano et al. [22], noted that technical errors play a significant role in TOT failure and reoperation, which can be reduced by translabial ultrasound. However, it should be noted that long-term studies demonstrated a low rate of TOT failure and need for reoperation, with a follow-up period of nearly 13 years [23]. Other systematic reviews demonstrated similar findings [8, 16]. In the present study, we demonstrated that the use of surgeon-tailored mesh was associated with a similar risk of failure and reoperation compared to traditional mesh. Our findings are similar to the reports by ElSheemy et al. [9, 10] and Chen et al. [18].

To our knowledge, only a few reports have attempted to explore the outcomes of surgeon-tailored mesh for SUI patients undergoing TOT; nonetheless, we acknowledge the existence of several limitations in our trial. Our study was limited to single-center only, and all procedures were done by the same surgeons, which can affect the generalizability of our findings. In addition, the sample size was relatively small. The postoperative voiding functions have not also been assessed using validated tools.

In conclusion, surgeon-tailored mesh for SUI patients undergoing TOT is a cost-effective strategy that is associated with a comparable long-term cure rate and incidence of long-term complications to the traditional costly meshes. The present trial confirmed that the surgeon-tailored mesh was associated with a similar cure rate and incidence of late complications compared to the traditional meshes at the end of the second year of follow-up. Thus, surgeons should consider these low-cost meshes, especially in low-resource settings. Nonetheless, the current published literature is still limited by the low number of published cases and low quality of published reports; thus, further studies are needed to characterize the outcomes of surgeon-tailored mesh for SUI patients undergoing TOT. Larger multicenter studies should confirm our results.

Availability of data and materials

All relevant data are within the manuscript. Additional patient data can be requested from the corresponding authors upon reasonable reason.

Abbreviations

TOT:

Trans obturator tape

SUI:

Stress urinary incontinence

MUS:

Mid-urethral sling

PVS:

Pubo-vaginal sling

TVT:

Tension-free vaginal tape

ALPP:

Abdominal leak point pressure

US:

Ultrasonography

References

  1. Komesu YM, Schrader RM, Ketai LH, Rogers RG, Dunivan GC. Epidemiology of mixed, stress, and urgency urinary incontinence in middle-aged/older women: the importance of incontinence history. Int Urogynecol J. 2016;27(5):763–72.

    Article  Google Scholar 

  2. Pandey D, Maturi C, Dhakar BPS, Jain G, Kyalakond K. Interventions and quality of life in stress urinary incontinence. Gynecol Minim Invasive Ther. 2019;8(3):106–12.

    Article  Google Scholar 

  3. Karim NB, Lo TS, Nawawi EA, Wu PY. Review on midurethral sling procedures for stress urinary incontinence. Gynecol Minim Invasive Ther. 2015;4:33–6.

    Article  Google Scholar 

  4. Ford AA, Rogerson L, Cody JD, Aluko P, Ogah JA. Mid-urethral sling operations for stress urinary incontinence in women. Cochrane Database Syst Rev. 2017;7(7):CD006375.

    PubMed  Google Scholar 

  5. Ogah J, Cody JD, Rogerson L. Minimally invasive synthetic suburethral sling operations for stress urinary incontinence in women. Cochrane database Syst Rev. 2009;4:CD006375.

    Google Scholar 

  6. Jain P, Jirschele K, Botros SM, Latthe PM. Effectiveness of midurethral slings in mixed urinary incontinence: a systematic review and meta-analysis. Int Urogynecol J. 2011;22:923–32.

    Article  Google Scholar 

  7. Jiao B, Lai S, Xu X, Zhang M, Diao T, Zhang G. A systematic review and meta-analysis of single-incision mini-slings (MiniArc) versus transobturator mid-urethral slings in surgical management of female stress urinary incontinence. Medicine. 2018;97:e0283.

    Article  Google Scholar 

  8. Leone Roberti Maggiore U, Finazzi Agrò E, Soligo M, Li Marzi V, Digesu A, Serati M. Long-term outcomes of TOT and TVT procedures for the treatment of female stress urinary incontinence: a systematic review and meta-analysis. Int Urogynecol J. 2017;28:1119–30.

    Article  Google Scholar 

  9. ElSheemy MS, Elsergany R, ElShenoufy A. Low-cost transobturator vaginal tape inside-out procedure for the treatment of female stress urinary incontinence using ordinary polypropylene mesh. Int Urogynecol J Pelvic Floor Dysfunct. 2015;26(4):577–84.

    Article  Google Scholar 

  10. ElSheemy MS, Fathy H, Hussein HA, Elsergany R, Hussein EA. Surgeon-tailored polypropylene mesh as a tension-free vaginal tape-obturator versus original TVT-O for the treatment of female stress urinary incontinence: a long-term comparative study. Int Urogynecol J. 2015;26(10):1533–40. https://doi.org/10.1007/s00192-015-2725-6.

    Article  PubMed  Google Scholar 

  11. Sayeda E, Ahmed A, Shebl M, Salah E. Assessment of correction of female stress urinary incontinence with trans obturator tape; traditional versus tailored. Med J Cairo Univ. 2021;89(6):845–50.

    Article  Google Scholar 

  12. JAVA. Declaration of Helsinki world medical association declaration of Helsinki. Bull World Health Organ. 2013;79(4):373–4.

    Google Scholar 

  13. Moher D, Hopewell S, Schulz KF, Montori V, Gøtzsche PC, Devereaux PJ, et al. CONSORT 2010 explanation and elaboration: updated guidelines for reporting parallel group randomised trials. Int J Surg. 2012;10:28–55.

    Article  Google Scholar 

  14. Wu Y, Welk B. Revisiting current treatment options for stress urinary incontinence and pelvic organ prolapse: a contemporary literature review. Res Rep Urol. 2019;11:179–88.

    PubMed  Google Scholar 

  15. Imamura M, Hudson J, Wallace SA, Maclennan G, Shimonovich M, Omar MI, et al. Surgical interventions for women with stress urinary incontinence: Systematic review and network meta-analysis of randomised controlled trials. BMJ. 2019;365:l1842.

    Article  Google Scholar 

  16. Tommaselli GA, Di Carlo C, Formisano C, Fabozzi A, Nappi C. Medium-term and long-term outcomes following placement of midurethral slings for stress urinary incontinence: a systematic review and metaanalysis. Int Urogynecol J Pelvic Floor Dysfunct. 2015;26:1253–68.

    Article  Google Scholar 

  17. Lo K, Marcoux V, Grossman S, Kung R, Lee P. Cost comparison of the laparoscopic burch colposuspension, laparoscopic two-team sling procedure, and the transobturator tape procedure for the treatment of stress urinary incontinence. J Obstet Gynaecol Can. 2013;35(3):252–7.

    Article  Google Scholar 

  18. Chen X, Jiang M, Tong X, Li H, Qiu J, Shao L, et al. A modified inexpensive transobturator vaginal tape inside-out procedure versus tension-free vaginal tape for the treatment of SUI: a prospective comparative study. Arch Gynecol Obstet. 2011;284(6):1461–6. https://doi.org/10.1007/s00404-011-1871-4.

    Article  PubMed  Google Scholar 

  19. Chen X, Li H, Fan B, Yang X, Tong X. An inexpensive modified transobturator vaginal tape inside-out procedure for the surgical treatment of female stress urinary incontinence. Int Urogynecol J Pelvic Floor Dysfunct. 2009;20(11):1365–8. https://doi.org/10.1007/s00192-009-0961-3.

    Article  CAS  PubMed  Google Scholar 

  20. Wu M-P, Long C-Y, Liang C-C, Weng S-F, Tong Y-C. Trends in reoperation for female stress urinary incontinence: a nationwide study. Neurourol Urodyn. 2015;34(7):693–8.

    Article  Google Scholar 

  21. Stav K, Dwyer PL, Rosamilia A, Schierlitz L, Lim YN, Lee J. Risk factors of treatment failure of midurethral sling procedures for women with urinary stress incontinence. Int Urogynecol J. 2010;21(2):149–55.

    Article  Google Scholar 

  22. Illiano E, Trama F, Li Marzi V, Mancini V, Carrieri G, Ruvolo CC, et al. Translabial ultrasound: a non-invasive technique for assessing “technical errors” after TOT failure. Int Urogynecol J. 2021. https://doi.org/10.1007/s00192-021-04897-6.

    Article  PubMed  Google Scholar 

  23. Tulokas S, Rahkola-Soisalo P, Gissler M, Mikkola TS, Mentula MJ. Long-term re-procedure rate after mid-urethral slings for stress urinary incontinence. Int Urogynecol J. 2020;31(4):727–35.

    Article  Google Scholar 

Download references

Acknowledgements

The author thanks Dr. Sayeda E, Aly and Dr. Ahmed A. El Gammal (urology department faculty of medicine for girls Al-Azhar University) for their participation in short-term outcomes of surgeon tailored mesh in patients with SUI undergoing TOT.

Funding

The authors declare that they have no funding.

Author information

Authors and Affiliations

Authors

Contributions

SES was responsible for data collection, study design, and final revision and proofreading of the final draft, data analysis, presentation, the writing process, and agreed that the final version of the manuscript was ready for publication. The author read and approved the final manuscript.

Corresponding author

Correspondence to Salah E. Shebl.

Ethics declarations

Ethics approval and consent to participate

The protocol of the current trial was approved by the local ethics committee of the Faculty of Medicine for Girls Al-Azhar University, Cairo, Egypt. (Study ID 202106892) Then, written informed consent was obtained from all participants. All procedures run in compliance with the standards of the Declaration of Helsinki.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Shebl, S.E. Two-year outcomes of surgeon-tailored trans obturator tape for female stress urinary incontinence: a randomized, comparative, trial with traditional trans obturator tape. BMC Urol 21, 155 (2021). https://doi.org/10.1186/s12894-021-00922-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12894-021-00922-4

Keywords